Large-aperture Superconductive MRI
Adopt the advanced magnet system, combined with intelligent shimming technology to achieve high homogeneity.
·Bringing large FOV, off-center quality images.
·Ensures a wide range of fat saturation imaging, shortens the FS sequence scan time and improves image quality.
Dynamic B0 Eddy Current Compensation Technology
The real-time compensation based on the state of eddy current improves fat suppression, reduces DWI image artifacts, and improves the image quality of B0 eddy current sensitive sequences such as SWI.
Fully Digitized
Optical Fiber Transmission
Completely digitalized acquisition system, gradient system and RF system are adopted to optical fiber transmission, which effectively reduce signal attenuation and keep the system isolated from external electromagnetic signal interference, ensuring efficient and stable transmission and improved image quality.
Power Sense
Fast Imaging System
Integrating traditional “Sense” and AI-based compressed sensing “Power Sense” fast imaging technology, the acquisition mode is optimized, and the scanning speed and image quality of MRI examinations are improved.
Subsecond Intelligent Shimming Technology
Being able to complete fast and precise shimming of any part and any area in 1 sec., bringing the homogeneity of the magnetic field to a maximum of 0.002ppm. It is almost unaffected by motion artifact, due to the extremely fast shimming process.
24/32 Channel RF Platform
The multi-channel coil corresponds independently to the multi-channel spectrometer, with fast parallel acquisition technology to improve imaging speed.
Integrated Coils
Wide range imaging can be performed by combined coils without the need of changing coils, that reduced the examination time.
70cm large aperture provides more people with a comfortable examination experience
The large aperture leaves patients more relaxed during scanning, which alleviates the feeling of space oppression for claustrophobic people reducing the use of sedation, for an examination more effective and safer.
Allowing people lying either flat or sideways with ease by enough space, and the SAR value control scheme and uniform RF field optimization technology ensure qualified abdominal imaging.
The examination space is enlarged so that women in the middle and late stages of pregnancy can achieve fast and accurate fetal imaging in a comfortable position and in a calm mood, without putting stress on their cardiopulmonary function.
Accommodate the patients with spinal disorders in a comfortable position to complete the examination smoothly with high-quality spinal imaging.
The wide space allows wrist, shoulder or elbow to be placed closer to the center of the magnet so that to acquire better image.
The larger aperture provides sufficient space to accommodate the breast coil. At the same time, the patient can have a more comfortable and natural posture and take the examination calmly.
Contact Us
010-84575792/3/5/6
international@wandong.com.cn